2864 Old Rochester Road
Springfield, IL 62703
Phone (217) 753-8424 – Fax (217) 753-8426
www.mid-tech.com
3. Program
Function Display Possible actions Comments
1. Access
Exit
Push Pro for 3 seconds
Push Pro for 3 seconds
Master must be off
2. Width Setup
Width
Setup
Pro to access Width setup
to modify the width value
Master must be off
3. Speed Setup
Speed
Setup
Pro to access Speed setup
Manual Calibration
to modify speed sensor cal #
Auto Calibration
CLR to access auto calibration
Mark off a known distance of 300ft / 100m
Pro to Start auto calibration
Drive the 300ft / 100m course
Pro to End auto calibration
Pro to Save calibration #
Master must be off
When using the Auto
calibration procedure it is best
to mark a course on a surface
that best matches real-time
operations. For the best
results repeat the Auto
calibration procedure 3 times
and take an average. Each run
should produce a similar cal #.
4. Alarms
Function Display Possible actions Comments
1. Alarm 1
Speed
Distance
Area
Alarm 1
Pro to access Alarm 1
to select alarm options (None,
Distance, Speed, or Area)
Pro to access Distance, Speed, or Area
to adjust alarm value of Distance,
Speed, or Area.
CLR to clear alarm message during
operation.
CLR for 3 seconds to clear alarm value and
reset Alarm.
NO audible alarm.
Alarm 1 output (gray wire) is
+12v when Alarm 1 is active.
During real-time operation the
alarm value must be exceeded
for at least 3 consecutive
seconds to activate alarm.
Displayed Speed, Distance, or
Area must be cleared or
reduced below Alarm value to
reset alarm.
2. Alarm 2
Speed
Distance
Area
Alarm
2
Pro to access Alarm 2
to select alarm options (None,
Distance, Speed, or Area)
Pro to access Distance, Speed, or Area.
to adjust alarm value of Distance,
Speed, or Area.
CLR to clear alarm message during
operation.
CLR for 3 seconds to clear alarm value and
reset Alarm.
Audible alarm.
Alarm 2 output (yellow wire) is
+12v when alarm 2 is active.
During real-time operation the
alarm value must be exceeded
for at least 3 consecutive
seconds to activate alarm.
Displayed Speed, Distance, or
Area must be cleared or
reduced below Alarm value to
disable alarm.