Teejet FENDT-INTERFACE Instrukcja Użytkownika Strona 3

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 4
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 2
3
3: Monitor-cable. Each wire is provided with a number which corresponds to the
numbers of the plugs on the rear of the monitor.
4: Socket for connection of an external area counting on/off sensor.
PIN FUNCTION
1 Signal
2 + 12 Volt (output for sensor)
3 0 Volt
SWITCH 1:
This switch changes between stop of area counting by the lift or by an external sensor (see plug
4 above).
Signal from external sensor.
Signal from lift.
SWITCH 2:
This switch chooses which speed sensor is to be used.
Signal from gear box (wheel).
Signal from radar (if mounted).
Przeglądanie stron 2
1 2 3 4

Komentarze do niniejszej Instrukcji

Brak uwag