21
98-05173 R1 US
ISOBUS Job Computer : IC18 Spreader NA
OVERVIEWSETUPAPPENDIX GETTING STARTEDOPERATION
MACHINE
Machine congures machine settings. Options include Filling, Operation, Implement Parameters, Calibrations,
Alarm Congurations and OEM.
MAIN SETUP MODE MENU STRUCTURE
| | | | | |
Counters Job Parameters Machine User Interface Communication Help
Filling
Operation
Implement parameters
Pulses per Volume – Calibrations
Implement Speed Sensor Alarm congurations
OEM
The OEM setup menu is password protected and the settings in this menu are directly related to the tted OEM equipment.
Figure 3-15: Machine
1. From the Main Setup Screen , select MACHINE.
2. Select from:
►Filling – establishes the amount of material
remaining in the bed.
►Operation – establishes Speed Source, and
Simulated Speed.
►Implement Parameters – establishes the Working
Width, Fast Empty Bed RPM and Master Switch
location.
►Calibrations – establishes either manual or
automatic settings of the sensors.
►Alarm Congurations – establishes alarms on or off
as well as sets their trigger level
►OEM – The OEM setup menu is password protected and the settings in this menu are directly related to the
tted OEM equipment. Refer to the OEM manual for information regarding OEM settings.
NOTE: Settings are NOT automatically saved when selected. The ACCEPT KEY must be selected to save
the setting. Select the ESCAPE KEY to escape without saving settings and return to the previous
menu.