ISOBUS Job Computer : IC18 Spreader European
Operation
Figure 3-17: Operation
Figure 3-18: Implement parameters
Figure 3-19: Fast Empty Key
Operation establishes Speed Source and Simulated Speed.
Speed Source
Speed Source selects whether to base the machine’s speed on input from the
CAN, an Implement or a Simulated source. Selecting “Implement” will allow for
the conguration of pulses per 100 meters. Selecting “Simulated” will allow for
simulated speed to be entered using the “Edit Value” option. Selecting “CAN”
allows for speed being supplied by the ISOBUS CAN (usually from the TECU) to be
used.
To select the Speed Source, select an option from the drop down menu or use
the UP/DOWN ARROWS to highlight the option.
NOTE: If “Implement” is selected, refer to the Calibrations section for further
instructions.
Simulated Speed
Simulated Speed establishes a speed to be used when using the Simulated Speed
source.
To select the Simulated Speed, use the number pad or slide bar.
Implement Parameters
Implement Parameters establishes the the Working Width, Fast Empty Bed RPM
and Master Switch location.
Working Width
Working Width establishes the desired distance between each adjacent pass while
spreading.
To select the Working Width, use the number pad or slide bar.
Fast Empty Bed RPM
Fast Empty Bed RPM establishes the revolutions per minute of the roller used to
drive the conveyor during the Fast Empty.
To select the RPM, use the number pad or slide bar.
The availability of Fast Empty is established in the OEM menu under Program
Modes. When set to "On", the Fast Empty Key will be available on the Home
Screen.
Master Switch
Master Switch is used to allow the operator to choose between a “remote master”
switch or the Start/Stop Key.
To select the Master Switch, select an option from the drop down menu or use
the UP/DOWN ARROWS to highlight the option.