26
www.teejet.com
OVERVIEW SETUP APPENDIXGETTING STARTED OPERATION
ISOBUS Job Computer : IC18 Spreader European
Calibrations
Pulses per Volume
Description Factory Setting Range User Setting
Pulses per Volume 0.0 /ft
3
0.0 /cm
3
0.0 - 5000 /ft
3
0.0 - 1500.0 /cm
3
Implement Speed Sensor
Description Factory Setting Range User Setting
Pulses per Distance 0 ft
0 m
0 - 30000 /300 ft
0 - 40000 /100 m
Alarm Congurations
Description Factory Setting Range/Options User Setting
Amount Remaining Alarm On/Off Off On
Off
Amount Remaining Trigger Level 0 lb
0 kg
0 - 9000 lb
0 - 4500 kg
CAN Speed Source Timeout 4 sec 0 - 999 sec
Active Trip Count Information Off On
Off
Spinner RPM Alarm On/Off Off On
Off
Spinner RPM Trigger Level 0 RPM 0 - 9999 RPM
USER INTERFACE
Description Factory Setting Options User Setting
Use Perferred VT Off Off
On
APPENDIX B - UNIT SPECIFICATIONS
Dimensions 19.05 x 18.42 x 6.03 cm
Weight 0.644kg
Connector 30 position Cinch pins. A1-K3
30 position Cinch pins. L1-Y3
Environmental Operating -40 to +85°C
Humidity 90% non-condensing
Input/Output ISO 11783 (ISOBUS)
Power Requirement <9 watts @12 VDC