Teejet Legacy 6000 Manual Instrukcja Użytkownika Strona 34

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 159
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 33
Legacy 6000
98-05053 R2
29
Figure 2-23: Servo Settings
Table 2-9: Servo Settings
Settings Description
Gain Speed at which the Control Channel reacts to an off-target condition. Decrease to slow
down the reaction; increase to speed up reaction (settings too high can result in oscilla-
tion).
Start Up Drive Drive level used to open valve only from full closed position. Increase if valve opens too
slowly and decrease if valve opens too quickly.
Master Switch Control valve response to all booms (OFF). Master Hold - Control valve will hold in the
same position. Closed - Control valve will drive full closed.
Implement Status Control valve response to when the Implement Status switch is open (OFF). Hold - Con-
trol valve will hold in same position. Closed - Control valve will drive full closed.
Valve Delay Delay in resuming control after turning booms ON from HOLD. When the control valve is
set to close, this feature is deactivated. When Master ON, valve will delay control for the
set value.
Valve Location Location of the control valve in the plumbing (In-Line or Bypass). Combination in-line/
bypass valves like the Autorange valve and most hydraulic servos use the In-line setting.
Figure 2-24: PWM Settings
Przeglądanie stron 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 158 159

Komentarze do niniejszej Instrukcji

Brak uwag